SecamCCTV DS 8001 master MOD-2304

Brend: SecamCCTV
Kod proizvoda: SecamCCTV DS 8001 master MOD-2304
Dostupnost: Na lageru
Cena: 63,720.00 RSD
Bez PDV-a: 53,100.00 RSD

DeviceMaster 4-Port serial device server with DB9 connectors and dual Ethernet ports

The DeviceMaster UP Modbus provides an RS-232, RS-422 or RS-485 software-selectable serial connection to an Industrial Ethernet network.

Simultaneously connect both serial and Ethernet devices to PLCs and/or applications with DualConnectPlus™ technology. String, RFID, and barcode data filtering eliminates redundant data while extracting the RFID and barcode parameters.


Includes:
  • DeviceMaster UP 4 Port DB9 2E Device
  • DIN Rail 
  • Installation Quick Start 
  • DB9 Loopback plug
  • DIN-rail mounting and DB9 connections
  • Wide operating temperature ranges (-40º C to 75º C)
  • Surge protection for serial ports
  • Wide DC Input Voltage Power (5 - 30VDC)
  • Support for Modbus RouterModbus/TCP, or Modbus Server
  • Dual Ethernet ports for daisy chaining network connections between multiple units
  • Four serial ports with DB9M
  • DualConnectPlus™ technology
  • SSL & SSH management, SSL serial data stream encryption
  • Software Controllable integrated 120Ω Termination Resistor for both the Transmit and Receive side in RS-422/485 Mode
  • NEMA TS2 Certified
  • UL Safety Certified
Hardware
  • Interface Specification10/100 BASE-T Ethernet
  • Memory
    • SDRAM32 MB
    • Flash8 MB
  • EnclosureUL94-V0 PLASTIC
  • Installation MethodDIN Rail (35mm)
  • Network Protocols AvailableModbus Router (default)
    Modbus Server
    Modbus/TCP
  • LED IndicatorsStatus, Ethernet Port Link and Activity
  • Dimensions4.6" x 3.9" x 1.8" 
    116.8 x 99.1 x 45.7 mm 
  • Product Weight0.45lbs 
    204.12g 
Electrical Specifications
  • Input Voltage Requirements5-30VDC
  • Power Consumption (Maximum)3.0 Watts
  • Power Input RedundancyDual Redundant Power Input
  • ESD Surge ProtectionProvided minimum of 25KV protection on all serial lines. All Ethernet components are rated to 1.5KV magnetic surge protection.
Environmental Specifications
  • Air temperature
    • System On-40 to 75° C
    • System Off-40 to 85° C
  • Operating Humidity (non-condensing)0% to 95%
  • Altitude0 to 10,000 Feet 
    3,048 m 
  • MTBF (Mean Time Between Failures)42.3 Years

Serial Communications

  • Connector TypeDB9 Male
  • Number of Ports4
  • Serial InterfacesRS-232
    RS-422
    RS-485 2-Wire
    RS-485 4-Wire (Master/Slave)
  • Termination Resistor for RS422/485Software controllable 120Ω termination resistors available for each transmit and receive differential pair on every port. The 120Ω termination resistors can be enabled between TX+ and TX- OR RX+ and RX- or both on every port
  • Baud Rate300 to 230Kbps
    • Receive Buffer4.5KB
    • Transmit Buffer4.5KB
  • Serial Port Control
    • Data Bits5, 6, 7 or 8
    • Parityodd, even, mark, space, or none
    • Stop Bits*1, 1.5, or 2
    • Flow ControlHardware, Software, None
    • * Stop bit 1.5: Supported only when used with 5 data bits
Ethernet Specifications
  • Number of Ports2
  • Speed10/100Mbps
  • Connector TypeRJ45F Auto MDI/MDI-X
  • LEDEthernet Link (Green)
    Ethernet Activity (Amber)
  • Ethernet Specific FeaturesEthernet packet switching, Auto Negotiation, Link/Activity Status LED
  • Network ProtocolsARP, BOOTP, DHCP/RARP, HTTP, HTTPS, SSH, SSL/TLS, SNMP (MIB-II), Telnet, and TFTP, and supports IP multicast data transmission
Modbus Router Features (Default)
  • DescriptionPure Modbus, multiple Modbus master and slave types , remote, local, and private devices
  • Supported InterfacesPLCs, SCADA systems, HMIs, OPC servers and applications
  • Web Page Configuration• Master-to-master connectivity via the Shared Memory sub-system 
    • Private Modbus serial bus support designed to restrict access to private Modbus devices 
    • Connectivity from serial Modbus masters to Modbus/TCP networks 
    • The ability to connect multiple types of Modbus masters to Modbus slave device(s) 
    • Convert from one form of Modbus, such as Modbus/TCP, to Modbus/RTU or Modbus/ASCII 
    • Provide connectivity from a serial Modbus master to a remote Modbus slave device 
    • Eliminate Modbus device ID conflicts and solve device ID configuration problems 
    • Enable Modbus security by blocking write messages in Read-Only Mode 
    • Device ID to Modbus/TCP slave via configurable IP address and TCP/IP port 
    • Modbus Network Bridging support
  • DiagnosticsLocal and remote slave device and port specific diagnostic web pages that display status, message response timing, timeout and other error counts, and overall message statistics. A serial log is also included to provide message level diagnosis.
Modbus Server Features (Downloadable)
  • DescriptionModbus/RTU over Ethernet master(s) to serial slave(s)
  • Supported InterfacesOPC Servers and Applications that require Modbus/RTU communication over Com ports or Ethernet TCP/IP connections
  • Web Page Configuration• Supports Modbus/RTU over Ethernet TCP/IP connections to the corresponding serial port via intelligent Modbus message handling and routing. 
    • Supports only Modbus/RTU over Ethernet TCP/IP connections to a serial port. For Modbus/TCP functionality, please see the DeviceMaster UP. 
    • Supports up to six Ethernet TCP/IP connections to each serial port. 
    • Supports up to 255 Modbus devices per port. Both valid, (1-247), and reserved, (248-255), device ids are supported 
    • Modbus/RTU specific message handling: ◦CRC verification of all messages received on the TCP/IP and serial interfaces 
    • Timing out of responses from slave Modbus/RTU devices 
    • Broadcast message handling on connected port only 
    • System monitoring to ensure gateway operation: 
    • Gateway busy 
    • Application message timeouts 
    • Combined with a serial port redirector, such as the Comtrol Secure Port Redirector, can support up to six COM port connections to each serial port
  • Diagnostics• Modbus device specific statistics, response timing, and status. Up to 255 devices per serial port can be monitored simultaneously.
    • Serial port specific statistics and status 
    • Serial port message logging
Modbus/TCP Features (Downloadable)
  • Supported InterfacesPLC, SCADA system, HMI, or OPC Server
  • Supported Controllers• Modbus/TCP masters and slaves 
    • Modbus/RTU and Modbus/ASCII serial masters and slaves 
    • Applications over Ethernet TCP/IP connections (raw/ASCII only)
  • Supported Devices• Raw/ASCII devices, both serial and Ethernet TCP/IP, such as barcode scanners, vision systems, RFID readers, weigh scales, encoders and printers 
    • Modbus/RTU and Modbus/ASCII serial slaves
  • Recommended Installations• Connectivity to serial and/or Ethernet TCP/IP raw/ASCII devices 
    • Connectivity to Modbus/RTU and/or Modbus/ASCII serial devices 
    • Connecting single or multiple Modbus masters and/or applications to the devices 
    • Automatic Modbus protocol translations (if needed)
  • Web Page Configuration• Highly flexible, with an emphasis on Raw/ASCII devices 
    • Also supports Modbus RTU/ASCII slave devices 
    • Connect Raw/ASCII devices to Modbus/TCP and Modbus RTU/ASCII serial controllers 
    • Automatic protocol conversions and routing 
    • Connect Modbus/TCP and Modbus RTU/ASCII serial masters to Modbus RTU/ASCII serial slaves 
    • Many unique Raw/ASCII handling features 
    • Simultaneously connect multiple Modbus masters to individual devices 
    • Modbus message Alias Device ID conversions
  • DiagnosticsYes
  • Sample PLC ProgramsYes
Features
  • SNMP SupportMonitoring Only
  • Other Software FeaturesPortVision DX remote management
  • Manufacturer's Warranty5 Years
Export Information
  • Packaged Shipping Weight0.85lbs 
    386g 
  • Package Dimensions5-11/16" x 5-11/16" x 3 3/8" 
    144.46 x 144.46 x 85.73 mm 
  • UPC Code7-56727-99612-5
  • Country of OriginUSA
  • ECCN5A992 
  • Schedule B Number8471.80.1000
Regulatory Approvals
  • EmissionsFCC Part 15 Subpart B: Class A limit
    Canadian EMC Requirements: ICES-003
    European Standard EN61000-6-4
    European Standard EN55022
    AS/NZS CISPR 22
  • ImmunityEuropean Standard EN61000-6-2 
    European Standard EN55024
    IEC 1000-4-2/EN61000-4-2: ESD
    IEC 1000-4-3/EN61000-4-3: RF
    IEC 1000-4-4/EN61000-4-4: Fast Transient/Burst
    IEC 1000-4-5/EN61000-4-5: Surge
    IEC 1000-4-6/EN61000-4-6: Conducted Disturbance
    IEC 1000-4-8/EN61000-4-8: Magnetic Field
    IEC 1000-4-11/EN61000-4-11: Dips and Voltage Variations
  • SafetyUL 61010-1, UL 61010-2-201
    CSA C22.2 No. 61010-1-12
    CSA C22.2 No. 61010-2-201:14
  • Other Regulatory ApprovalsEuropean Standard: RoHS 2 Compliant under CE
    NEMA TS2 COMPLIANT

       

  • Pinout Diagram

       


  • 99612-5-DMUP-4Port-DB9-2E-Modbus-1

    99612-5-DMUP-4Port-DB9-2E-Modbus-1



Slicni proizvodi:
DAHUA PFS3006-4ET-60
TIP: PoE Switch, Ukupan Broj Portova:

5,876.40 RSD


HIKVISION DS-3E0105P-E
TIP: PoE Switch, Ukupan Broj Portova:

pozvati za cenu


DAHUA PFS3005-4P-58
TIP: PoE Switch, Ukupan Broj Portova:

7,080.00 RSD


HIKVISION DS-3E0106HP-E
TIP: PoE Switch, Ukupan Broj Portova:

pozvati za cenu


DAHUA PFS3005-4ET-60-V2
TIP: PoE Switch, Ukupan Broj Portova:

7,788.00 RSD


DAHUA PFS3006-4ET-60-V2
TIP: PoE Switch, Ukupan Broj Portova:

9,204.00 RSD


HIKVISION DS-3E0505HP-E
TIP: PoE Switch, Ukupan Broj Portova:

pozvati za cenu


DAHUA PFS3106-4T
TIP: Switch, Ukupan Broj Portova:

11,328.00 RSD